Qingdao Primus Innovative Technology Ltd.
The free call:400-666-7855

Super card troubleshooting

2015-07-15 15:10:00 source: BOZHI Soft

A super card, how to solve the problem of buffer overflow?
1 protection card in the case of the incremental copy of the Ctrl+Enter Explorer mode or Enter protection mode to install software and change the protection of the partition of the data will occupy buffer, if in the case of the buffer zone continues to grow to normal circumstances, such as to remove the buffer to do permanent incremental copy buffer can be removed;
2 engine room machine after a network copy, into the main mode (Ctrl+Enter) installation software in the process of the buffer overflow, the solution: please do not install too much in the main mode of the software, install software to check the buffer occupancy rate, the buffer occupancy of more than 70% before the installation of the software incremental transmission, and then continue to install new software. Cut do not wait for the buffer occupancy rate of the card to more than 90% copies, so prone to some of the non predictable error;
3 if there is a need for a long time on the machine, and then the boot process needs to carry out a large number of data exchange, then proposed that the machine system partition using the B property of the backup is also a prototype boot partition, select manual reduction method to maintain the basic operating system, backup also prototype boot partition is not required to install the protection card system internally driven, there will not be a buffer zone growth;
4 if the Ctrl+Enter mode into the operating system in the incremental mode to change a lot of things that cause the buffer overflow in the protection card into the state, the machine can not work properly. Solution: that the machine has been unable to work, if the normal working of the machine will be in Ctrl + enter mode write buffer data clear all can, in the protective card system is set up for the partition information, will be the restoration of the corresponding operating system change does not protect the backward operating system can empty the buffer data, the system is restored to the state before the installation of new software, if it is used in the engine room, to change a normal machine to install the software, do incremental copy preparation.

Two, how to achieve the partition (other types of partitions can also be according to this) the hidden
Chaoba card hidden partition: will be hidden partition modify property c operating system guide partition save restart the computer, then enter the protected card system settings in the boot settings interface operating system get rid of the control of the operating system and the partition under any operating system are not visible.
Three, how to make the operating system will never support incremental.
1, Chaoba card only after the completion of the transmission manually remove the incremental copy options to support the state does not support incremental copy, after network copy will once again to support incremental copy;
Four, the network wake up how to achieve?
Network wake-up function, need to meet the following conditions:
1, the need to support the motherboard, the motherboard up on LAN Wake option must be turned on, the host to open the network to wake up the switch to use the network, the network tool in the transmission of CMOS functions, transmission to the receiving end;
2, in the protection of the card network copy interface, so that all the machine after landing, in the IP address of the re allocation options, the lower left corner there is a "bound current allocation information" option must be selected (selected to make the protection card records list of each machine MAC address, the protection card number and MAC address bound up, only the MAC address of the machine can be network wake up).
Five, why do you enter an operating system after the shutdown can not wake up?
To achieve network wake-up requires the main board card in the computer off state card lights, network card can communicate with the switch, but part of the network card driver in the operating system, the operating system will be shut down to save power. Specific solutions are as follows:
1, open mode to enter the operating system, the Wake of my computer right key attribute - > system properties - > Device Manager - > network adapter - > select the On Lan After Shutdown;
2, my computer right key attribute - > system properties - > Hardware - > Device Manager - > network adapter - > select the right key properties - > power management - > will allow the computer to turn off this device to save power of the hook removed.
By modifying these two options, after entering the operating system will not shut down the network card will not shut down, it will not make the function of network wake-up failure.

 Six, the first boot can not be achieved after the power of the engine room to wake up, wake up after the network is normal.第Six, the first boot can not be achieved after the power of the engine room to wake up, wake up after the network is normal.
Network wake up the realization of the need to support the main board, power supply and power consumption can only provide the minimum power requirements of the computer on the motherboard, the various devices on the motherboard contains no load, so can not achieve the network copy. After power on the main board of the various parts of the power supply, so you can realize the network wake up.
Seven, super card, why not the first time out of the boot after installation interface?
1, into the BIOS settings, BOOT First to LAN/Network boot or Restcard protection card to start;
2, check the BIOS equipment list and see whether there is to find our network equipment, if not, please replace the slots or re insert the Speedmaster card;
3, the Speedmaster display card press [Ctrl+H] to setup network receiver. Prompt, press F4, different hardware boot mode (the default boot mode is 0, can be changed to 1 / 2 / 3)
4, for another super card
Eight, the card after the restart of the computer to restart the computer can not enter the protection card installation interface,
After the installation is complete, restart the computer to stop at loading please, wait Now right lower corner to display the error message
A) 01 detect hard drive, detect hard disk device, or change the hard disk option;
B) 02 detection of network card, network cable, card and other non - Liang may be in here to stop, or 30 seconds after the detection of the past;
C) 03 detection of the mouse, no plug the mouse will stop in this position;
D) 04 detection and protection of the card graphics interface, -54, -53 hard disk read and write, re install the protection card driver or change the hard disk type option;
E) network initialization error, please re configure the network card, click OK after the next step;
F) appear above the question may restart the computer, in the command / Ctrl + H position press Ctrl + F6 will skip over detection information into the protective card operating system radio interface, F6 in special settings modify the hard drive, Chaoba card F6 into special set to modify network type; shielding mouse F6 in standard drive select 4 can be.
Now) loading please, wait G does not appear any information, it is recommended that the customer Ctrl+F6 in the bottom of the unloading protection card driver to install.
Nine, the installation, the point to start the installation, and automatically jump back to this interface, can not read the disc, the left corner of the cursor can not be installed.
1, drive error, please confirm CD-ROM is inserted in the drive disc right;
2, restart once, to do once the installation process;
3, CD-ROM was not found, please set the CMOS interface to see if BIOS has detected CD-ROM;
4, the BIOS setting in the starting sequence is set to CDROM for the first boot, at the beginning of the installation interface by the combination Ctrl+B;
5, you can change the CMOS in the CD-ROM mode, the best setting is Compatible (compatible) mode;
6, the replacement of different brands and models of CD-ROM;
7, the use of floppy disk installation (on each disc drive disk have a file that can be used to manufacture the floppy disk, CD-ROM directory Floppy.exe file);
8, the use of U disk installation program, production can be started to the DOS interface of the U disk, the protection of the UPD file in the disk file copy to the U disk, running one of the install.exe file to guide the protection card driver;
9, the upper left corner of the computer, the middle position of a gray square box, graphics card in the DOS can not start the high resolution, the need to replace the installation procedures, the use of low resolution drivers for installation.
Ten, partition, temporary storage area how to divide? How much is appropriate?
In the partition, set up the system partition, the buffer bar will automatically open, the default state is 1004M we can manually adjust. In general we recommend buffer size for 5-10% of all the corresponding protection zoning capacity, according to the system to install the software and use appropriate settings. Super card buffer can set the range of 100Mbytes---5GB for static adjustable storage. (Primus Max default buffer blue 502M card, a version of the default is 1004M,).
Eleven, the installation system need to use open mode to enter the installation?
No need We in the setup of the system, the system installation disk into the drive, guide the order for CD-ROM boot, in GP card operating system boot menu choose to install the system, directly enter can be installed to protect the card a property operating system is not installed on the upper drive, attribute B operating system without manual build information backup system is not protected.
 
Twelve, why do you copy the data after the installation of the operating system to protect the card drivers?
With the protection card for the operating system partition in the installation of the operating system can not be modified, so in the installation of the operating system, you need to directly select the partition directly installed, you can not delete the partition to re partition the action.
Thirteen, super card windows driver when installed?
1, after the installation of the system, the load of computer hardware driver and application software, and then install a variety of hardware windows driver. Set the computer name and IP, DNS, and so on... , can be installed on the top of the protection card, this driver once installed; a, if the protection card is set to protect the protection of one, the system will be the system as the reduction reference point; B, if the installation is not protected when the card is set to protect, restore point set to a time when the restore point.
2, after installing the super driver card operating system, restart the system after the start protection.
Fourteen, DOS operating system when to start protection
1, DOS operating system must be DOS (the size of the write can be) to support the protection
2, once the DOS protection partition format, restart after the start to protect
Fifteen, have installed a Windows card driver, want to increase the software, is to open into the installation?
Chaoba card can in protected mode and open mode (Ctrl + Enter) software installation, need to pay attention to is in protected mode after software installation restart computer in the system menu interface according to the Ctrl+b write data, otherwise it will be the newly written data loss.
Sixteen, install super card windows driver prompt data partition unformatted, verb for protection?
Chaoba card windows drivers need to be all of the operating and disk installed after the completion of the set and executed the installation, namely, the first format all partition to install the upper drive. As mentioned above, the user only needs to format the data disk, restart the computer can be normal.
Seventeen, back up the original installation of the operating system, need to install the protection card windows driver?
Super Card No. Because the backup and recovery system is carried out by manual backup of, directly to the system partition and cloned into the corresponding buffer and restoring the backup partition does not support the computer name and IP address allocation.
18, why Chaoba card partitions, you can set the FAT32 file system, but the system is installed in is cannot be formatted as FAT32 partition, can only format into NTFS?
This is because the operating system has a limit to the size of the FAT32 partition, and the WINDOWS system only supports less than the 32G partition using the FAT32 format.
In nineteen, when using a super card, how to reinstall the operating system (for installation and new installation)
1, enter the F10 system management interface, click on the "operating system settings" option, into the corresponding operating system of advanced settings, the operating system will be the incremental support state of the hook removed
2, to the partition of the operating system to set the corresponding boot partition of the boot partition is set to do not protect, save restart computer;
3 to enter the operating system, into the control panel, click Add / remove program";
4, the super card upper driverunload;
5, restart the computer, install the operating system, hardware drivers and other software, set up a good system of computer name and IP address, restart the computer;
6, into the F10, to the partition of the operating system to set up the corresponding boot partition of the reduction method is set to protect";
7, enter the operating system, install a card upper driver, restart the computer, to complete the operation.
Twenty, if a shared partition in exclusive partition and boot partition in front (physical location), how can the sharing partition in Windows assign a drive letter will be shared partitions placed in the back of the letter
The first way: in installing the operating system into the operating system, the right button click "my computer", select "manage", choose "disk management", partition of the letter for manual adjustment;
The second way: at the end of partition will share disk by S type changed to C type, and then install the operating system, exclusive formatted partition, such agency partition will occupied front, after the restart, the C type changed back to s type into the operating system to format the partition.
Two one, how to re lock the machine's connection number, there is a standardized operation steps?
1, the transmitter operating system boot menu, press F8 to enter in, choose the network copy.
2, the network copy of the sending end for logon -- > > ---- > complete logon;
3, select the receiver side";
4, select "IP", will "lock the current distribution of information" is not checked, click "confirm";
5, the sending end is set to wait for the login status, according to the set of the order of the receiving end, followed by the;
6, when all the receiving end are in order to log in, choose to re assign IP, click the automatic allocation";
7, check the election on the current distribution of the lock information, click to confirm, so that the connection can be re locked;
8, binding sign in the installation process of the binding part of the landing number.

 1, the replacement of the hard disk or network card after any one, log on to the host, the host will automatically be the original landing number assigned to the machine without re setting, only need to re assign IP address interface click once identified can be noticed: automatic allocation function is based on the connection number 1 machine information as the starting value, if there is no connection number is 1 of the machine log on, automatic allocation of functions can not be used, only manual changes.
Two two, change the machine or network card, hard drive how to change to the original login number?
1, the replacement of the hard disk or network card after any one, log on to the host, the host will automatically be assigned to the original landing number of the machine without the need to re set, only need to re allocate the IP address of the interface once determined to;
2, the network card and hard disk at the same time to re visit the host, the host will give a new login number to the machine (the original state of the log number +1), need to use the host network to install the receiver driver, accept the end into the network interface, the landing number is changed to the original login number, will use the modified landing number, and then re assign IP address interface to determine;
3, the change of the new machine to change the registration number is the same as the 2.
Two or three, when the receiver is damaged, can not appear operating system boot menu and can automatically connect, how to do?
"[Ctrl+H] to setup network Receiver Press (xx/xx/xxxx), when starting, press the keyboard +H key CTRL. Forced to log in manually, through the sending end to the machine to re install the receiver. Note (xx/xx/xxxx) to protect the hardware version of the card
Two four, if you want to backup an operating system ghost, in what time is appropriate?
1, a backup operation system best in installation Chaoba card upper drive before, complete this ghost operating system, is not easy;
2, if the ghost ghost imaging to the hard disk corresponding to the operating system, please before the ghost will correspond to the operating system of windows driver uninstall, and in the "system management" interface will be the boot partition is set to "no protection", and then start the ghost operation system, in the system management interface will be boot partition design for protection, into the operating system installed Chaoba card driver, ghost completed
Two five, the use of automatic ghost disc installation operating system, why the operating system is not installed on the boot disk (not start)?
1, the automatic ghost optical disc installation operation system is installed in the disk of the first partition of the first partition, if you can boot disk in front of the exclusive or shared disk, the installation process will be installed in front of a partition
2, to solve this problem, please confirm whether it is in the operating system can guide the division of the front is also divided into exclusive partition, if it is, then please change to manual use Ghost way, choose ghost to your needs of the target set up.
Two six, Ghost installed operating system, using the normal host, after the transfer is complete all receiver restart after the blue screen
1, part of the brand of hard disk drive problems in ghost operating system support, first install the operating system must use operating system installation disk step by step installation, after the completion of the installation of the operating system transmission can be used normally, if the ghost installation will appear blue screen phenomenon.
2, brand machine has its own OEM version of the operating system, easy to install or retained after installation, host is no problem, is transmitted to the receiver after receiving end blue screen or the file is missing, the problem can only be re install the operating system.
How to allocate IP function two seven, super card use?
Super card "automatically assign IP" function is based on the line No. 1 machine down automatically added
1, if there is no connection number is 1 of the machine log on, you can not use the automatic allocation function, the automatic allocation option is not available, can only choose to manually modify the function or the function of the distribution.
2, the Speedmaster card automatically assign IP interface, as long as the tick on the lock to the current distribution information, after all the receiving end login sequence and IP value will be fixed to live, after every time the network copy or is incremental copy do not need to automatically assign IP this work (without adding new machines), just into the assigned IP address in the list click OK,
If there is no new machine to join, every time to enter the re allocation of IP function, directly click to confirm that you can.
Two eight, the "re allocation of IP" function how to use?
1, the "re distribution of IP" function only need to do once in the installation, do not do it, unless there is a new machine to join or need to re assign the machine IP and the connection number;
2, after the implementation of the "IP", click on the "receiving end restart", this time in the receiving end driver will automatically determine whether the new distribution of the IP value is the same as the previous IP address value, if not the same will automatically enter the operating system update IP address, will not enter;
Note: the automatic allocation function is based on the connection number is 1 of the machine information as the starting value of the automatic allocation, if there is no connection number is 1 of the machine log on, the automatic allocation of functions can not be used, can only be changed manually.
 
How to give a single operating system IP address allocation, two nine super card operating system?
1, in the use of multi operating system, if you are directly in the distribution of IP address of the list of the address, the protection of the card will be one by one to enter all the A attributes to protect the normal distribution of the IP address;
2, to a single operating system to allocate IP address, you need to put the IP address of the allocation action on the network copy data, that is, first, the IP address, then send the corresponding operating system data;
3, if the network has been completed, to a single operating system IP address, you can use the function of incremental copy IP address, that is, in the incremental copy interface to allocate IP address, then send incremental copy of the data.
Thirty, super card connection distribution in how to use the IP address
1, the protection of the distribution of the functions in the absence of log number for a machine with special settings, we take 48 machines, for example, such as the computer name is not from A1~A48, but B1~B8, C1~C8, D1~D8, E1~E8, A1~A8, F1~F8, A1~A48, B1, A1, we can use the following;
1, the use of computer name A1 2 select automatic allocation, so the machine computer name is A1~A48, we choose the 9 machine input computer name for B1 to choose the A1~A8, B1~B40,, and then select the 17 machine input computer name C1 choose to continue to be assigned, then the computer name is A1~A8, B1~B8, C1~C32. Once and so on, until we achieve the effect we need, this method is also applied to the allocation of IP addresses;
3, the use of continuous distribution we can effectively reduce the workload of similar distribution in the allocation of IP addresses and computer name.
Three one, super card "incremental copy" what conditions use?
1, the operating system is to restore the way, and the reduction is not to use, but the protection of a state;
2, install the operating system protection card under the upper drive, protect the right of the computer card protection monitor normal feet;
3, the receiving end and the transmitting section together do a network copy, and in the network copy after the host or the receiving end does not change the protection card is not used;
4, F10 "system management" in the "incremental set" list of "operating system incremental copy of the state" in the corresponding operating system in front of the option is selected.
Three two, in the use of incremental copy, why some of the receiving end of the red font, the machine state error, do not support incremental copy"
1. The network copy of the operating system has not been done before and after the receiving end;
2, "advanced settings" option in the receiving end of the "system management" "operating system settings" in view of this operating system is "Incremental Support" the tick is selected, if has done before the operation to copy the operating system increment, the operating system will does not support incremental copy;
3, the last time to do incremental copy of these machines because some of the reasons do not work with other machines to do incremental copy, then these machines and the host's reduction is different, so can not be synchronized to do incremental copy;
4, the machine that changed the hard disk, it does not use the protection function, can also damage increment copy;
The solution to the problem: the host to enter the network copy interface, will not support the incremental copy of the machine to visit the transmission section, the machine can automatically support the incremental copy of the network after the copy of the machine, then you can support incremental copy.
Three three, the engine room to do, in the late maintenance, whether any one machine can be used as an incremental copy of the sending end?
Can, if all machines are in the unified network copy, unified incremental copy of the state, later to do incremental copy can be any one machine to do incremental copy.

CONTACT US
TEL:400-666-7855

Legal Notices | Privacy protection | Contact us | Sitemap
All Rights Reserved © Primus Inc. 2000-2014 All rights reserved Lu ICP 07502060 No.